Protezioni Contro Le Sovratensioni

Finmotor surge arrester series was designed to improve equipment protection. Surge arresters are installed near the end of any conductor which is long enough before the conductor lands on its intended electrical component. The purpose is to divert damaging over-voltage transients caused by external (lightning) or internal (switching) events safely to ground. Also called a surge protection device (SPD) or transient voltage surge suppressor (TVSS), they are designed to protect against electrical transients resulting from a lightning flash, not a direct lightning termination, to the conductors.

All models include remote contact, a visual indicator and comply with the UL 1449, IEC 61643-11, and VDE 0675 International Standards.  DIN rail mounting options are available and select models are unpluggable offering the option to replace specific cards as needed.

To view the Surge Arrester catalog, please click here.  

AM

  • Classe I
  • Applicazione da 1 a 4 poli
  • Tensione nominale 120-600 Vac
  • Indicatore visivo
  • Contenitore metallico
  • SCCR fino a 300 KA

BG (G) 25

  • Classe I+II
  • Applicazione da 1 a 4 poli
  • Tensione nominale 120-600 Vac
  • Massima corrente di scarica per fase 100 KA, Neutro 200 KA
  • Indicatore visivo e contatto remoto
  • Montaggio guida DIN

BG (G) 50

  • Classe I+II
  • Applicazione da 1 a 4 poli
  • Tensione nominale 120-600 Vac
  • Massima corrente di scarica per fase 150 KA, Neutro 200 KA
  • Indicatore visivo e contatto remoto
  • Montaggio guida DIN

BM (G) 12.5

  • Classe I+II
  • Applicazione da 1 a 4 poli
  • Tensione nominale 120-600 Vac
  • Massima corrente di scarica per fase 80 KA, Neutro 100 KA
  • Indicatore visivo e contatto remoto
  • Montaggio guida DIN

EMG (G) 20

  • Classe II+III
  • Applicazione da 1 a 4 poli
  • Tensione nominale 120-600 Vac
  • Massima corrente di scarica 40 KA
  • Indicatore visivo e contatto remoto
  • Sostituibile

EMG (G) 40

  • Classe II+III
  • Applicazione da 1 a 4 poli
  • Tensione nominale 120-600 Vac
  • Massima corrente di scarica per fase 80 KA, Neutro 80 KA
  • Indicatore visivo e contatto remoto
  • Montaggio guida DIN
  • Sostituibile

EMG (G) 60

  • Classe II+III
  • Applicazione da 1 a 4 poli
  • Tensione nominale 120-600 Vac
  • Massima corrente di scarica per fase 120 KA, Neutro 120 KA
  • Indicatore visivo e contatto remoto
  • Montaggio guida DIN
  • Sostituibile

FINPR

  • Classe II
  • Applicazione da 1 a 4 poli
  • Tensione nominale 120-600 Vac
  • Massima corrente di scarica per fase 50 KA, Neutro 50 KA
  • Indicatore visivo e contatto remoto
  • Montaggio guida DIN
  • Sostituibile

FINPRS

  • Classe II
  • Applicazione per DC
  • Tensione nominale 500-1200 Vdc
  • Massima corrente di scarica 50 KA
  • Indicatore visivo e contatto remoto
  • Montaggio guida din
  • Sostituibile
Finmotor Facebook
Web Site Design and Hosting by Saco Design | Powered by Site Avenger CMS