Surge Arrester/ Protection

Finmotor surge arrester series was designed to improve equipment protection. Surge arresters are installed near the end of any conductor which is long enough before the conductor lands on its intended electrical component. The purpose is to divert damaging over-voltage transients caused by external (lightning) or internal (switching) events safely to ground. Also called a surge protection device (SPD) or transient voltage surge suppressor (TVSS), they are designed to protect against electrical transients resulting from a lightning flash, not a direct lightning termination, to the conductors.

All models include remote contact, a visual indicator and comply with the UL 1449, IEC 61643-11, and VDE 0675 International Standards.  DIN rail mounting options are available and select models are unpluggable offering the option to replace specific cards as needed.

To view the Surge Arrester catalog, please click here.  

AM

  • Class I
  • 1 to 4 poles application
  • Rated voltage 120-600 Vac
  • Visual indicator
  • Metal enclosure
  • SCCR up to 300 KA

BG (G) 25

  • Class I+II
  • 1 to 4 poles application
  • Rated voltage 120-600 Vac
  • Max Nominal discharge phase 100 KA, Neutral 200 KA
  • Visual and remote contact indicator
  • DIN rail mounting

BG (G) 50

  • Class I+II
  • 1 to 4 poles application
  • Rated voltage 120-600 Vac
  • Max nominal discharge phase 150 KA, Neutral 200 KA
  • Visual and remote contact indicator
  • DIN rail mounting

BM (G) 12.5

  • Class I+II
  • 1 to 4 poles application
  • Rated voltage 120-600 Vac
  • Max nominal discharge phase 80 KA, Neutral 100 KA
  • Visual and remote contact indicator
  • DIN rail mounting

EMG (G) 20

  • Class II+III
  • 1 to 4 poles application
  • Rated voltage 120-600 Vac
  • Max discharge current 40 KA
  • Visual and remote contact indicator
  • Replaceable

EMG (G) 40

  • Class II+III
  • 1 to 4 poles application
  • Rated voltage 120-600 Vac
  • Max nominal discharge phase 80 KA, Neutral 80 KA
  • Visual and remote contact indicator
  • DIN rail mounting
  • Replaceable 

EMG (G) 60

  • Class II+III
  • 1 to 4 poles application
  • Rated voltage 120-600 Vac
  • Max nominal discharge phase 120 KA, Neutral 120 KA
  • Visual and remote contact indicator
  • DIN rail mounting
  • Replaceable 

FINPR

  • Class II
  • 1 to 4 poles application
  • Rated voltage 120-600 Vac
  • Max nominal discharge phase 50 KA, Neutral 50 KA
  • Visual and remote contact indicator
  • DIN rail mounting
  • Replaceable 

FINPRS

  • Class II
  • DC application
  • Rated voltage 500-1200 Vdc
  • Max nominal discharge 50 KA
  • Visual and remote contact indicator
  • DIN rail mounting
  • Replaceable 